国际肿瘤学杂志 ›› 2024, Vol. 51 ›› Issue (6): 321-325.doi: 10.3760/cma.j.cn371439-20240215-00055

• 论著 • 上一篇    下一篇

血清miR-106b-5p、miR-760联合低剂量螺旋CT诊断早期肺癌的临床价值

刘娜(), 寇介丽, 杨枫, 刘桃桃, 李丹萍, 韩君蕊, 杨立洲   

  1. 河北省沧州市人民医院CT放射科,沧州 061000
  • 收稿日期:2024-02-15 修回日期:2024-03-19 出版日期:2024-06-08 发布日期:2024-06-28
  • 通讯作者: 刘娜,Email: s20njo@163.com
  • 基金资助:
    沧州市重点研发计划(222106039)

Clinical value of serum miR-106b-5p and miR-760 combined with low-dose spiral CT in the diagnosis of early lung cancer

Liu Na(), Kou Jieli, Yang Feng, Liu Taotao, Li Danping, Han Junrui, Yang Lizhou   

  1. Department of CT Radiology, Cangzhou People's Hospital of Hebei Province, Cangzhou 061000, China
  • Received:2024-02-15 Revised:2024-03-19 Online:2024-06-08 Published:2024-06-28
  • Contact: Liu Na, Email: s20njo@163.com
  • Supported by:
    Key Research and Development Plan in Cangzhou City(222106039)

摘要:

目的 探讨微RNA(miR)-106b-5p、miR-760在早期肺癌患者血清中的水平以及联合低剂量螺旋CT在诊断早期肺癌中的临床价值。方法 收集2022年1月至2023年3月于河北省沧州市人民医院进行治疗的90例早期肺癌患者(肺癌组)作为研究对象,同时选取同期90例经病理确诊为肺部良性病变(良性肺结节)的患者作为对照组。比较两组患者血清miR-106b-5p、miR-760水平,对低剂量螺旋CT检查结果进行分析;绘制受试者操作特征曲线,确定血清miR-106b-5p、miR-760的最佳截断值;四格表分析血清miR-106b-5p、miR-760联合低剂量螺旋CT对早期肺癌的诊断效能。结果 肺癌组患者血清miR-106b-5p水平高于对照组(1.39±0.31比1.04±0.30),血清miR-760水平低于对照组(0.75±0.24比1.02±0.26),差异均有统计学意义(t=7.70,P<0.001;t=7.24,P<0.001)。miR-106b-5p、miR-760、低剂量螺旋CT诊断早期肺癌的曲线下面积(AUC)分别为0.83、0.81、0.82,准确率分别为76.67%、77.22%、81.67%,敏感性分别为84.44%、81.11%、76.67%,特异性分别为68.89%、73.33%、86.67%。血清miR-106b-5p、miR-760联合低剂量螺旋CT诊断早期肺癌的AUC为0.96,准确率为90.00%,敏感性为94.44%,特异性为85.56%。三项联合诊断的准确率高于miR-106b-5p、miR-760、低剂量螺旋CT单独诊断(χ2=11.52,P=0.001;χ2=10.72,P=0.001;χ2=5.14,P=0.023);三项联合诊断的敏感性高于miR-106b-5p、miR-760、低剂量螺旋CT单独诊断(χ2=4.77,P=0.029;χ2=7.46,P=0.006;χ2=11.51,P=0.001);三项联合诊断的特异性高于miR-106b-5p、miR-760单独诊断(χ2=7.11,P=0.008;χ2=4.12,P=0.042)。结论 早期肺癌患者血清miR-106b-5p水平显著升高,miR-760水平显著降低,miR-106b-5p、miR-760联合低剂量螺旋CT对早期肺癌具有较高的诊断价值。

关键词: 肺肿瘤, 诊断, 微RNA-106b-5p, 微RNA-760, 低剂量螺旋CT

Abstract:

Objective To investigate the levels of microRNA (miR)-106b-5p and miR-760 in the serum of early lung cancer patients, and the clinical value of the combination of them and low-dose spiral CT in the diagnosis of early lung cancer. Methods Ninety early lung cancer patients (lung cancer group) who underwent treatment in Cangzhou People's Hospital of Hebei Province from January 2022 to March 2023 were collected as research subjects, meantime, 90 patients with benign pulmonary lesions (benign pulmonary nodules) diagnosed by pathology were selected as the control group. The levels of miR-106b-5p and miR-760 in the serum of two groups were compared, the results of low-dose spiral CT examination were analyzed; receiver operating characteristic curve was drawn to determine the optimal cut-off values of serum miR-106b-5p and miR-760; four grid table method was applied to analyze the diagnostic efficacy of serum miR-106b-5p, miR-760 combined with low-dose spiral CT for early lung cancer. Results The level of miR-106b-5p in lung cancer group was higher than that in control group (1.39±0.31 vs. 1.04±0.30), serum miR-760 level was lower than that in control group (0.75±0.24 vs. 1.02±0.26), with statistically significant differences (t=7.70, P<0.001; t=7.24, P<0.001). The area under curve (AUC) of miR-106b-5p, miR-760 and low-dose spiral CT in the diagnosis of early lung cancer was 0.83, 0.81 and 0.82, the accuracy was 76.67%, 77.22% and 81.67%, the sensitivity was 84.44%, 81.11% and 76.67%, and the specificity was 68.89%, 73.33% and 86.67%, respectively. The AUC, accuracy, sensitivity, and specificity of serum miR-106b-5p, miR-760 combined with low-dose spiral CT in diagnosing early lung cancer were 0.96, 90.00%, 94.44%, and 85.56%, respectively. The accuracy of the three combined diagnosis was higher than that of individual diagnosis of miR-106b-5p, miR-760 and low-dose spiral CT (χ2=11.52, P=0.001; χ2=10.72, P=0.001; χ2=5.14, P=0.023), the sensitivity of the three combined diagnosis was higher than that of individual diagnosis of miR-106b-5p, miR-760 and low-dose spiral CT (χ2=4.77, P=0.029; χ2=7.46,P=0.006; χ2=11.51, P=0.001), the specificity of the three combined diagnosis was higher than that of individual diagnosis of miR-106b-5p, miR-760 (χ2=7.11, P=0.008; χ2=4.12, P=0.042). Conclusion The serum level of miR-106b-5p is significantly increased in early lung cancer patients, while the serum level of miR-760 is significantly reduced. The combination of miR-106b-5p, miR-760 and low-dose spiral CT has high diagnostic value for early lung cancer.

Key words: Lung neoplasms, Diagnosis, MicroRNA-106b-5p, MicroRNA-760, Low-dose spiral CT